The switch controlled unit (as with the LCU) can be installed within an existing panel or enclosure (images shown above), or supplied pre-mounted into an enclosure.
The SCU releases key(s) after switching the knob into a visible off
position.
• Direct drive operation – positively opens contacts
• Available as 20A, 32A and 63A variants
• Most common contact arrangements are 2NO/2NC &
4NC. Other contact arrangements available on request
• Mild steel construction as standard
• Stainless steel construction as standard in combination with
CLSS or MLSS lock types
• Special switch ratings, and/or contact arrangements
available on request.

Khóa interlock SCU1-1-0-CLIS-V-A02022-H01CB. Công tắc điều khiển bằng núm. Switch Controlled Unit (SCU) – Knob operated Switch. Công tắc ngắt mạch khẩn cấp dùng để cách ly nguồn cấp (điện) khỏi hệ thống.

Khóa interlock SCU1-1-0-CLIS-V-A02022-H01CB.

 

Thông tin đặt hàng Khóa interlock SCU1-1-0-CLIS-V-A02022-H01CB FORTRESS

Các công tắc màu đỏ và vàng chỉ nên được sử dụng để dừng khẩn cấp / tắt khẩn cấp cho các ứng dụng mà hoạt động dừng hoàn toàn ở tốc độ tối đa (đối với tất cả các nguồn năng lượng nguy hiểm). Ở những nơi sử dụng công tắc để cách ly, chúng phải có màu xám và đen.

Sản phẩm này được thiết kế để sử dụng theo hướng dẫn cài đặt và vận hành kèm theo. Nó phải được cài đặt bởi nhân viên có năng lực và trình độ đã đọc và hiểu toàn bộ tài liệu này trước khi bắt đầu cài đặt. Bất kỳ sửa đổi hoặc sai lệch nào so với các hướng dẫn này đều làm mất hiệu lực của tất cả các bảo hành.Thiết bị này là một thành phần được thêm vào hệ thống lắp đặt điện cố định đáp ứng các yêu cầu của tiêu chuẩn IEC/EN hiện hành. Tất cả các điện áp được sử dụng trên các thiết bị đầu cuối LCU / SCU đều phải cùng loại.

Standard Functionality

Normally In Locks have keys trapped when the switch is in the ON position. The switch must be turned to the OFF position,
(or state of contact changed), before any of the keys can be removed. Once any of the Normally In Locks have keys removed,
the switch cannot be operated and power restored.

Technical SpecificationsLCU / SCU
Housing MaterialsMild steel with powder coat finish
Lock MechanismDie-cast zinc body with stainless operating mechanism (selected separately)
Minimum Operating Current5mA at 20v
   
Safety Data
StandardsEN60947-3: 2009
ISO EN14119: 2013
EN13849-1: 2008
EN13849-2: 2012
EN62061: 2005
CertificationsCE marked for all applicable directives
CategoryCat. 4, PLe (EN/ISO 13849-1) and SIL3 (EN/IEC 62061)
Functional safety dataB10d5,000,000
DCHigh 99% (with correct monitoring)

 

Technical SpecificationsLCU / SCU
Housing MaterialsMild steel with powder coat finish
Lock MechanismDie-cast zinc body with stainless operating mechanism (selected separately)
Minimum Operating Current5mA at 20v
   
Safety Data
StandardsEN60947-3: 2009
ISO EN14119: 2013
EN13849-1: 2008
EN13849-2: 2012
EN62061: 2005
CertificationsCE marked for all applicable directives
CategoryCat. 4, PLe (EN/ISO 13849-1) and SIL3 (EN/IEC 62061)
Functional safety dataB10d5,000,000
DCHigh 99% (with correct monitoring)

 